3.7 Selecting the Training Speed
The training speed selects how fast the transducer scans the display sector. Two choices are
available, 3° (normal speed, default setting) and 6° (high speed), and one may be selected with
the [FAST SCAN] key. Each time the key is pressed the display momentarily shows “NORM
(normal speed) or “FAST” (high speed).
Normal: 60 transmissions for half circle in increments of 3°.
High: 30 transmissions for half circle in increments of 6°.
3.8 Finding Echo Position with the Cursor
The cursor measures horizontal range and depth. Operate the Omnipad to place the cursor
where desired. Cursor data appears at the top left-hand corner on the screen.
NAV
DATA
Cursor
Cursor data
+→ : Horizontal range
: Depth
Figure 3-10 Location of cursor position data