7
The mounting procedure for flush mount (option)
Requires flush mount kit OP05-73 (optional supply). Prepare a cut-
out in the mounting location whose dimensions are as shown in the
Figure 3.
Flush Mount Kit (OP05-73)
.oNemaNepyTyt'Q.oNedoC
1etalptnuomhsulF1321-370-501182-932-001
2wercsgnippaT403SUS02x54048-208-000
3wercs.xeH61x8M2570-288-000
Figure 3 Mounting dimensions for flush mount
Duplexer Unit
General mounting consideration
Locate the unit in a place free of water spray and water splash.
Keep the unit out of direct sunlight because of heat that can build
up inside the unit.
Leave a little slack in cables to allow a service technician to move
the radio from its usual location with the cables connected. This
lets him make tuning and other adjustments on a "live" set.
Do not install the unit where flammable gases are stored.
Select a well ventilated area.
Ensure the mounting location is strong enough support the weight
of the unit (2.7 kg) under the condition of continued vibration nor-
mally encountered aboard the vesssel. If necessay, reinforce the
mounting area with a doubling plate or lining block.
Leave sufficient space at the sides and rear of the unit for mainte-
nance and service purposes and to provide for circulation of cool-
ing air.
Mounting the unit
Mount the unit with four tapping screws supplied.
150
205
261
10
max 14
25
20
106
10